Quick Link
Quick Contact
Address
No.367 Beijing Road, Longquanyi District, Chengdu, China
Tel
86--13981727059
Our Newsletter
Subscribe to our newsletter for discounts and more.
125mm Hydrocyclone Cluster Lightweight PU Liner Fine Particle Classification 8 Way
Fine classification is usually a space problem before it is a separation problem. Small diameter cyclones give the sharp cut that fine duty needs, but a single 125 mm unit cannot carry the flow, and a bank of them can become a maintenance liability. This cluster is arranged so the whole bank stays serviceable.
Each 125 mm cyclone uses a thin-wall shell with a one-piece cast polyurethane liner, which brings the individual unit weight down to a level one fitter can handle on a manifold. That changes installation entirely: the frame only has to carry the process load, not a bank of heavy steel cones.
A 125 mm body has little tolerance for wear. Because the liner is cast as one piece, the cone taper, the apex seat and the inlet geometry all stay to drawing, which is what keeps the classification curve steady on fine feeds. There is no joint at the apex end, the area that wears first and fastest.
Polyurethane resists hydrolysis and works across pH 2 - 13, so the same liner suits clay slurries, wash water and reagent-bearing process water without a material change. Individual units and spares are interchangeable across the bank, so one spares kit covers the whole installation.
| Liner Type | One-piece hot cast polyurethane (PU) liner |
| Liner Hardness | 88 - 92 Shore A |
| Housing Material | Carbon steel with anti-corrosion coating, SS304 optional |
| Feed Pressure | 0.06 - 0.25 MPa |
| Separation Range | 10 - 150 µm |
| Classification Efficiency | ≥ 85% |
| Underflow Spigot | Replaceable PU spigot, ceramic option |
| Overflow Vortex Finder | Replaceable PU vortex finder |
| Hydrolysis Resistance | ≥ 85% tensile retention after 168 h immersion at 70 ℃ |
| Corrosion Resistance | pH 2 - 13 slurry with chloride bearing water |
| Process Connection | Bolt-on flange / quick clamp, DN50 - DN200 |
| Spare Parts Kit | Apex spigot, vortex finder, inner liner, feed chamber, gaskets |
Kaolin and clay classification, fine silica and frac sand cut points, pigment and filler slurries, and any duty where 10 - 75 µm separation has to be achieved in a compact footprint.
Tell us your flow rate and target cut size and we will propose the number of units, apex bore and manifold arrangement.